   power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products with fuseholder 5x20 mm/6.3x32 mm, voltage sel. (series-parallel) fuse drawer, voltage selector insert and bowden - cable must be ordered separately. c14 70 c description - panel mount: screw-on mounting from front side - 5 functions: appliance inlet, line switch for bowdencable actuation, fuseholder with interchangeable fuse drawer for fuse-links 5 x 20 mm or 6.3 x 32 mm, voltage selectors (series-parallel), line filter in standard and medical version - quick connect terminals 4.8 x 0.8 mm - alternative: version without line filter kg-bowdencabl e - approvals - vde license number: 40004665 (fksa, fksb) - ul license number: e72928 (fksa, fksb) characteristics - all single elements are already partially wired - for added safety "extra-safe" fuse drawers are available fuse drawer meets requirements of medical standard iec/en 60601-1 the fuse drawer can only be opened with the aid of a tool the fuseholder is accessible from the equipment front - qualified for use in equipment according iec/en 60950 references general product informatio n weblinks approval s , roh s , china-roh s , mating connector s , distributor-stock- chec k , accessorie s technical data ratings iec 1 - 6 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 8 a @ ta 40 c / 125 vac; 60 hz leakage current medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 4.8 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm rated power acceptance @ ta 23 c 5 x 20: 2.5 w (1 pole)/ 2 w (2-pole) per pole 6.3 x 32: 3.15 w (1 pole)/ 2.5 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch switch for bowdencable 2-pole, non- illuminated, acc. to iec 61058-1 technical detail s voltage selectors series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch line filter iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'100'000 h acc. to mil-hb-217 f
 power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products dimensions 78 mm cg bowden cable 79.7 89 30 55 4.8x0.8 r 4.5 r 6 r 3.1 81 +0.3 0 0.15 97 69 27.2 ? 3.2 ? 6.3x90 28.5 +0.2 0 r 3 0 -0.2 89 230 2.8 m3/? 3.6 56 2 78 43.1 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 diagrams medical version with fuseholder 2-pole x) external connection to be made by the customer 1) line 2) load derating curves fuses 5 x 20 mm (1-pole) admissible power ac - ceptance in watt 1.5 1.0 0.5 0.0 2.5 2.0 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c fuses 5 x 20 mm (2-pole, per pole) admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c fuses 6.3 x 32 mm (1-pole) admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 1 00 1.5 1.0 0.5 0.0 2.5 3.15 2.0 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c fuses 6.3 x 32 mm (2-pole, per pole) admissible power ac - ceptance in watt per pole 1.5 1.0 0.5 0.0 2.5 2.0 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c
 power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products attenuation loss - - - - differential mode _____ common mode medical version (m5) 1 a 2 a 4 a 6 a 10 a variants fuse drawer, voltage selector insert and bowdencable must be ordered separately. type rated current [a] filter-type fuseholder line switch line switch order number cg-bowdencable 1 medical version (m5) 2-pole 2-pole switch for bowdencable cgg0.6199.151 cg-bowdencable 2 medical version (m5) 2-pole 2-pole rocker switch cga0.6199.151 cg-bowdencable 4 medical version (m5) 2-pole 2-pole switch for bowdencable cgc0.6199.151 cg-bowdencable 6 medical version (m5) 2-pole 2-pole switch for bowdencable cge0.6199.151 packaging unit 10 pcs required accessor y description bowdencables incl. accessor y bowden cable for power entry modules jumper wire 1 connection with stranded cable type b, 100 0881.0074 type b, 100 0881.0075 type a, 100 0881.0076 type a, 100 0881.0077 fusedrawer 1 fusedrawer for fuse links 5x20mm resp.. 6.3x32mm 5 x 20, 2-pole 4305.0001 6.3 x 32, 2-pole 4305.0011 5 x 20, 2-pole, shorting bar in the neutral side 4305.0021 6.3 x 32, 2-pole, shorting bar in the neutral side 4305.0026 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1
 power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products description voltage selectors insert 1 voltage selector insert to ke, ce, kg, cg 3 or 4 switch positions 4305.0048.00 1, 3 or 4 switch positions, 100, 120, 220, 240 4305.0048.01 3, 3 or 4 switch positions, 130, 110, 240, 220 4305.0048.02 2, 2 switch positions, 110, 220 4305.0048.03 ... accessorie s cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating outlets/connector s category / description appliance outlet overview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outlet further types to cg-bowdencabl e connector overview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connector further types to cg-bowdencabl e ... power cord overview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cord further types to cg-bowdencabl e ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.


▲Up To Search▲   

 
Price & Availability of CGG06199151

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X