power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products with fuseholder 5x20 mm/6.3x32 mm, voltage sel. (series-parallel) fuse drawer, voltage selector insert and bowden - cable must be ordered separately. c14 70 c description - panel mount: screw-on mounting from front side - 5 functions: appliance inlet, line switch for bowdencable actuation, fuseholder with interchangeable fuse drawer for fuse-links 5 x 20 mm or 6.3 x 32 mm, voltage selectors (series-parallel), line filter in standard and medical version - quick connect terminals 4.8 x 0.8 mm - alternative: version without line filter kg-bowdencabl e - approvals - vde license number: 40004665 (fksa, fksb) - ul license number: e72928 (fksa, fksb) characteristics - all single elements are already partially wired - for added safety "extra-safe" fuse drawers are available fuse drawer meets requirements of medical standard iec/en 60601-1 the fuse drawer can only be opened with the aid of a tool the fuseholder is accessible from the equipment front - qualified for use in equipment according iec/en 60950 references general product informatio n weblinks approval s , roh s , china-roh s , mating connector s , distributor-stock- chec k , accessorie s technical data ratings iec 1 - 6 a @ ta 40 c / 250 vac; 50 hz ratings ul/csa 1 - 8 a @ ta 40 c / 125 vac; 60 hz leakage current medical < 5 a (250 v / 60 hz) dielectric strength > 1.7 kvdc between l-n > 2.7 kvdc between l/n-pe test voltage (2 sec) allowable operation temp. -25 c to 85 c climatic category 25/085/21 acc. to iec 60068-1 degree of protection from front side ip 40 acc. to iec 60529 protection class suitable for appliances with protection class 1 acc. to iec 61140 terminal quick connect terminals 4.8 x 0.8 mm panel thickness s screw: max 8 mm mounting screw torque max 0.5 nm material: housing thermoplastic, black, ul 94v-0 appliance-inlet/-outlet c14 acc. to iec/en 60320-1, ul 498, csa c22.2 no. 42 (for cold conditions) pin-temperature 70 c, 10 a, protection class 1 fuseholder 1 or 2 pole, shocksafe category pc2 acc. to iec 60127-6, for fuse-links 5 x 20 or 6.3 x 32 mm rated power acceptance @ ta 23 c 5 x 20: 2.5 w (1 pole)/ 2 w (2-pole) per pole 6.3 x 32: 3.15 w (1 pole)/ 2.5 w (2-pole) per pole power acceptance @ ta > 23c admissible power acceptance at hig - her ambient temperature see derating curves line switch switch for bowdencable 2-pole, non- illuminated, acc. to iec 61058-1 technical detail s voltage selectors series-parallel, 4, 3 or 2 switch positions or usable as 2-pole change-over switch line filter iec 60939, iec 60601-1, ul 1283, ul 544, en 133 200, csa c22.2 no. 8 technical detail s mtbf > 1'100'000 h acc. to mil-hb-217 f
power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products dimensions 78 mm cg bowden cable 79.7 89 30 55 4.8x0.8 r 4.5 r 6 r 3.1 81 +0.3 0 0.15 97 69 27.2 ? 3.2 ? 6.3x90 28.5 +0.2 0 r 3 0 -0.2 89 230 2.8 m3/? 3.6 56 2 78 43.1 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1 diagrams medical version with fuseholder 2-pole x) external connection to be made by the customer 1) line 2) load derating curves fuses 5 x 20 mm (1-pole) admissible power ac - ceptance in watt 1.5 1.0 0.5 0.0 2.5 2.0 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c fuses 5 x 20 mm (2-pole, per pole) admissible power ac - ceptance in watt per pole 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n 2.0 1.5 1.0 0.5 0.0 ambient air temperature ta c fuses 6.3 x 32 mm (1-pole) admissible power ac - ceptance in watt 0 2 0 4 0 6 0 8 0 1 00 1.5 1.0 0.5 0.0 2.5 3.15 2.0 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c fuses 6.3 x 32 mm (2-pole, per pole) admissible power ac - ceptance in watt per pole 1.5 1.0 0.5 0.0 2.5 2.0 0 2 0 4 0 6 0 8 0 100 i = < < i n i = 0.7 i n i = 1.0 i n ambient air temperature ta c
power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products attenuation loss - - - - differential mode _____ common mode medical version (m5) 1 a 2 a 4 a 6 a 10 a variants fuse drawer, voltage selector insert and bowdencable must be ordered separately. type rated current [a] filter-type fuseholder line switch line switch order number cg-bowdencable 1 medical version (m5) 2-pole 2-pole switch for bowdencable cgg0.6199.151 cg-bowdencable 2 medical version (m5) 2-pole 2-pole rocker switch cga0.6199.151 cg-bowdencable 4 medical version (m5) 2-pole 2-pole switch for bowdencable cgc0.6199.151 cg-bowdencable 6 medical version (m5) 2-pole 2-pole switch for bowdencable cge0.6199.151 packaging unit 10 pcs required accessor y description bowdencables incl. accessor y bowden cable for power entry modules jumper wire 1 connection with stranded cable type b, 100 0881.0074 type b, 100 0881.0075 type a, 100 0881.0076 type a, 100 0881.0077 fusedrawer 1 fusedrawer for fuse links 5x20mm resp.. 6.3x32mm 5 x 20, 2-pole 4305.0001 6.3 x 32, 2-pole 4305.0011 5 x 20, 2-pole, shorting bar in the neutral side 4305.0021 6.3 x 32, 2-pole, shorting bar in the neutral side 4305.0026 technical data of filter-components rated current [a] filter-type inductances l [mh] capacitance cx [nf] capacitance cy [nf] r [m ? ] 1 medical version (m5) 2 x 10 68 - 1 2 medical version (m5) 2 x 4 68 - 1 4 medical version (m5) 2 x 1.5 68 - 1 6 medical version (m5) 2 x 0.8 68 - 1
power entry modules with line filter medical version cg-bowdencable www.schurter.com/pg0 6 emc products description voltage selectors insert 1 voltage selector insert to ke, ce, kg, cg 3 or 4 switch positions 4305.0048.00 1, 3 or 4 switch positions, 100, 120, 220, 240 4305.0048.01 3, 3 or 4 switch positions, 130, 110, 240, 220 4305.0048.02 2, 2 switch positions, 110, 220 4305.0048.03 ... accessorie s cord retaining kit s cord retaining strain relief flat head, a 4700.0001 mating outlets/connector s category / description appliance outlet overview complet e iec appliance outlet f, screw-on mounting, front side, solder terminal 478 7 iec appliance outlet f, snap-in mounting, front side, solder or quick-connect terminal 478 8 iec appliance outlet f or h, screw-on mounting, front side, solder, pcb or quick-connect terminal 509 1 iec appliance outlet f or h, screw-on mounting, front side, solder or quick-connect terminal 509 2 appliance outlet further types to cg-bowdencabl e connector overview complet e iec connector c15, rewireable, straight 010 1 iec connector c15a, rewireable, straight 010 2 iec connector c15a, rewireable, straight 0102- g iec connector c15a, rewireable, angled 011 2 iec connector c13, rewireable, angled 401 2 connector further types to cg-bowdencabl e ... power cord overview complet e power cord with iec connector c13, angled 031 1 power cord with iec connector c13, angled 301 1 power cord with iec connector c13, angled 301 2 power cord with iec connector c13, angled 301 3 power cord with iec connector c13 302 0 power cord further types to cg-bowdencabl e ... the specifications, descriptions and illustrations indicated in this document are based on current information. all content is subject to modifications and amendments.
|